Top of the page

Motordrevet kolbeburette, SI Analytics Titronic 500-M2/20, med 20 mL burettehoved

Item No. 9863212
Motor-driven piston burette TITRONIC® 500 Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparation of solutions by en

Beskrivelse

Motor-driven piston burette TITRONIC® 500

Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparation of solutions by entering the weights. The connection of an analytical balance allows the easy automatisation of the solution preparation. The TITRONIC® 500 can completely controlled from a PC via the USB- or RS-232-interface. Up to 16 burettes can be connected to one another via the RS232 interface according to the daisy chain principle.

T 500: TITRONIC® 500 basic unit without magnetic stirrer, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240.V

T 500-M1: TITRONIC® 500 basic unit with magnetic stirrer TM 235, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240V

T 500-M2/20: TITRONIC® 500 basic unit with magnetic stirrer TM 235 and exchangeable unit WA 20, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240V
Technical specification
Interfaces: 3x USB (2x USB A and 1x USB B), 2x RS-232-C
Stirrer connection: TM 235 or alternative paddle stirrer
Keyboard: The unit is operated using the keys on the device itself., the controller TZ 3880 and optional PC-keyboard (USB)
Display: graphics-capable 3,5'' TFT display
Volume display: 00.00 to 999.9ml
Display resolution: 0.001ml (depending on exchangeable unit)
Dosing speed: max. 100ml/min (with 50ml unit)
Filling speed: min. 20 to 999 sec adjustable (time according to the cylinder volume)
Exchangeable units: 5, 10, 20ml or 50ml exchangeable units with reagent recognition
Burette resolution: 10000
Dosing accuracy: systematic error 0.1%, random error 0.05% in compliance with EN ISO 8655-6
Netzanschluss: 100-240V; 50/60Hz
Conformity: ISO 8655, part 6
CE-mark: EMC: 2004/108/EG; safety EG- Directive 2006/95
Type T 500-M2/20
Description With magnetic stirrer and 20ml exchangeable unit

Pakningsstørrelse: 1 stk.

Specifikationer

Producent
SI Analytics
Pakningsstørrelse
1 stk.
Salgsenhed
EA
UNSPSC
41121808 Laboratorieburetter
Spørgsmål til produktet - kontakt
Kristoffer Laugesen, kla@buch-holm.dk, +45 44540022

Motordrevet kolbeburette, SI Analytics Titronic 500-M2/20, med 20 mL burettehoved

Item No. 9863212
Motor-driven piston burette TITRONIC® 500 Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparation of solutions by en

Beskrivelse

Motor-driven piston burette TITRONIC® 500

Motor-driven piston burette with intelligent exchangeable doing units with automatic recognition of unit size and reagent data. Besides manual titration and highly precise dosing tasks the TITRONIC® 500 can also be used for the preparation of solutions by entering the weights. The connection of an analytical balance allows the easy automatisation of the solution preparation. The TITRONIC® 500 can completely controlled from a PC via the USB- or RS-232-interface. Up to 16 burettes can be connected to one another via the RS232 interface according to the daisy chain principle.

T 500: TITRONIC® 500 basic unit without magnetic stirrer, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240.V

T 500-M1: TITRONIC® 500 basic unit with magnetic stirrer TM 235, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240V

T 500-M2/20: TITRONIC® 500 basic unit with magnetic stirrer TM 235 and exchangeable unit WA 20, with stand rod TZ 1510, titration clamp Z 305, controller TZ 3880, power supply 100-240V
Technical specification
Interfaces: 3x USB (2x USB A and 1x USB B), 2x RS-232-C
Stirrer connection: TM 235 or alternative paddle stirrer
Keyboard: The unit is operated using the keys on the device itself., the controller TZ 3880 and optional PC-keyboard (USB)
Display: graphics-capable 3,5'' TFT display
Volume display: 00.00 to 999.9ml
Display resolution: 0.001ml (depending on exchangeable unit)
Dosing speed: max. 100ml/min (with 50ml unit)
Filling speed: min. 20 to 999 sec adjustable (time according to the cylinder volume)
Exchangeable units: 5, 10, 20ml or 50ml exchangeable units with reagent recognition
Burette resolution: 10000
Dosing accuracy: systematic error 0.1%, random error 0.05% in compliance with EN ISO 8655-6
Netzanschluss: 100-240V; 50/60Hz
Conformity: ISO 8655, part 6
CE-mark: EMC: 2004/108/EG; safety EG- Directive 2006/95
Type T 500-M2/20
Description With magnetic stirrer and 20ml exchangeable unit

Pakningsstørrelse: 1 stk.

Specifikationer

Producent
SI Analytics
Pakningsstørrelse
1 stk.
Salgsenhed
EA
UNSPSC
41121808 Laboratorieburetter
Spørgsmål til produktet - kontakt