Gasanalysator MAT1100 m/elektrokemisk iltcelle

Item No. 6269834
Gas analyzer MAT1100 Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2). Applies to all models of MAT1000 series: -Easy and intuitive operation via touchscreen, even by untrained personnel -Create your own method -Available

Beskrivelse

Gas analyzer MAT1100
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).
Applies to all models of MAT1000 series:
-Easy and intuitive operation via touchscreen, even by untrained personnel
-Create your own method
-Available method parameters: scales, measurement procedures, limit values, comment and much more
-Selectable measurement methods: single or continuous
-Several single measurement procedures: manual, automatic, min/max detection
-Shortcut keys for most important functions
-Short measurement period, high accuracy even with small sample volume
-Validation possible
-Compliance with global standards such as GMP/GLP and 21 CFR Part 11
-Documentation of all measured values of the last 999 measurements
-Integrated interfaces, flexible data export (USB, Ethernet, RS-232)
-Compact design in robust cast aluminum housing
-Built-in air pressure sensor
-Integrated flow rate monitoring
Gas analysers for controlling protective gas packaging. The MAT1100 equipped with an electrochemical oxygen cell measures the oxygen concentration within the range of 0.5 and 35 vol% and with an accuracy of ±0.2 vol%. The MAT1200 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.

The MAT1100 is the right choice whenever you only need to be concerned with the oxygen concentration or whenever only nitrogen is used. Its electrochemical oxygen cell (EC) measures within the range of 0.5 and 35 volume per cent and with an accuracy of ±0.2 volume per cent. Unlike our other models, the MAT1100 requires very little time to heat up and can therefore be quickly used for occasional measurement or in case of frequent „changes of location“.

Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.
-Sporadic O2 sample checks
-Quick Operation
-Low-drift electrochemical oxygen cell (EC)
-Low-drift carbon non-dispersive infrared sensor (NDIR), model MAT1200
-Combined O2 and CO2 measurement, model MAT1200
-Environmental compensated CO2 measurement, model MAT1200

Specifications
Type MAT1100 with oxygen cell 
O2 measuring range: 0.5 to 35 Vol.-%
Accuracy: ±0.2 Vol.-%
Resolution: 0.1 Vol.-% 
CO2 measuring range (only MAT1200): 0 to 50 Vol.-%
Accuracy: ±0.5 Vol.-%
Resolution: 0.11 Vol.-%
Average measurment period: 7 sec
Heating time: <10 sec
Interface: RS-232, USB, Ethernet
Dimensions (W x D x H): 200 x 350 x 150 mm
Weight: 4.6 kg
Power consumption: 60 W
Power supply: 100-250 V, 50/60 Hz

Pakningsstørrelse: 1 stk.

Specifikationer

Producent
A. Krüss Optronic
Pakningsstørrelse
1 stk.
Salgsenhed
EA
UNSPSC
41116116 Miljømæssige testkit eller tilbehør
Spørgsmål til produktet - kontakt
Kundeservice, b-h@buch-holm.dk, +45 44540000

Gasanalysator MAT1100 m/elektrokemisk iltcelle

Item No. 6269834
Gas analyzer MAT1100 Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2). Applies to all models of MAT1000 series: -Easy and intuitive operation via touchscreen, even by untrained personnel -Create your own method -Available

Beskrivelse

Gas analyzer MAT1100
Gas analyzers MAT1000 series are used for measuring oxygen concentrations (O2) or optional carbon dioxide concentrations (CO2).
Applies to all models of MAT1000 series:
-Easy and intuitive operation via touchscreen, even by untrained personnel
-Create your own method
-Available method parameters: scales, measurement procedures, limit values, comment and much more
-Selectable measurement methods: single or continuous
-Several single measurement procedures: manual, automatic, min/max detection
-Shortcut keys for most important functions
-Short measurement period, high accuracy even with small sample volume
-Validation possible
-Compliance with global standards such as GMP/GLP and 21 CFR Part 11
-Documentation of all measured values of the last 999 measurements
-Integrated interfaces, flexible data export (USB, Ethernet, RS-232)
-Compact design in robust cast aluminum housing
-Built-in air pressure sensor
-Integrated flow rate monitoring
Gas analysers for controlling protective gas packaging. The MAT1100 equipped with an electrochemical oxygen cell measures the oxygen concentration within the range of 0.5 and 35 vol% and with an accuracy of ±0.2 vol%. The MAT1200 additionally features a non-dispersive infrared sensor for measuring carbon dioxide within the range of 0 and 50 vol% and with a high accuracy of ±0.5 vol%. Both devices are suitable for the random sampling as well as the permanent monitoring of the gas mixture used on packaging machines. Their solid metal housing with an interchangeable protective cover offers protection against impact and dirt from the outside.

The MAT1100 is the right choice whenever you only need to be concerned with the oxygen concentration or whenever only nitrogen is used. Its electrochemical oxygen cell (EC) measures within the range of 0.5 and 35 volume per cent and with an accuracy of ±0.2 volume per cent. Unlike our other models, the MAT1100 requires very little time to heat up and can therefore be quickly used for occasional measurement or in case of frequent „changes of location“.

Measurement of O2 and CO2 e.g. in modified atmosphere packaging, for work with modified atmosphere conditions.
-Sporadic O2 sample checks
-Quick Operation
-Low-drift electrochemical oxygen cell (EC)
-Low-drift carbon non-dispersive infrared sensor (NDIR), model MAT1200
-Combined O2 and CO2 measurement, model MAT1200
-Environmental compensated CO2 measurement, model MAT1200

Specifications
Type MAT1100 with oxygen cell 
O2 measuring range: 0.5 to 35 Vol.-%
Accuracy: ±0.2 Vol.-%
Resolution: 0.1 Vol.-% 
CO2 measuring range (only MAT1200): 0 to 50 Vol.-%
Accuracy: ±0.5 Vol.-%
Resolution: 0.11 Vol.-%
Average measurment period: 7 sec
Heating time: <10 sec
Interface: RS-232, USB, Ethernet
Dimensions (W x D x H): 200 x 350 x 150 mm
Weight: 4.6 kg
Power consumption: 60 W
Power supply: 100-250 V, 50/60 Hz

Pakningsstørrelse: 1 stk.

Specifikationer

Producent
A. Krüss Optronic
Pakningsstørrelse
1 stk.
Salgsenhed
EA
UNSPSC
41116116 Miljømæssige testkit eller tilbehør